Oil monitoring by using UV- stimulated Fluorescence
According to the national and international environmental laws concerning water
“every person is liable for taking the necessary precautions, according to the specific conditions, to prevent oil pollution of water”
It is very important that water of industrial plants never introduces oil into the process or into the environment.
For this reason, a continuous monitoring of water is necessary at the outlet of those plants, where oil emissions are possible in case of operational malfunctions.
The problem is, that produced water carries typically a considerable load of contaminations, e.g. sand, mud, algae or salts. Operation conditions such as temperature, speed of flow or water level are not constant. These changing process properties make it very difficult to get reliable oil monitoring results.
The measurement of the absolute oil amount in mg/l or ppm is not really possible by using the known inline & online measuring systems. The reasoning for this statement is, that oil is not homogeneous distributed in the water. The systems capture only a fraction of the total water quantity for analysis. The biggest quantity of the water is not measured, at installations in open channel, basin, tank or large pipes. Taking a representative sample with average oil content is virtually impossible, because the distribution of the oil fluctuates unpredictably within the water. The distribution is affected by parameters like water depth, temperature, speed of flow and oil type. As an example, very often you will find no oil in a water depth of 30cm, but there is an oil film on the water surface. Almost all types of oil or at least their components are lighter than water and therefore they float. Due to this property we can expect to get the highest oil concentration at the surface or in the upper region of large pipelines. The oil monitor model FLUCOmat uses the floating characteristic of oil to ensure maximum sensitivity
Review of different measurement methods
Various methods are used to detect oil in water:
- uv- stimulated fluorescence
- ir- reflection
- ultrasonic reflection
- absorption photometry
- conductivity measurements at the water surface
- capacitive measurements
- transfer of oil in a solvent for hydrocarbons & spectroscopic analysis of the solvent
- light scattering turbidimetry
- transfer oil hydrocarbons to gas phase (e.g. stripping with air) and their detection
into the gas phase (e.g. with a FID)
Most applications concern water that contains contaminants as like sand, salts, algae, mud, etc. beside the oil.
These particles can considerably falsity the measurements. Methods requiring contact with the fluid, e.g. flow cells or dipping electrodes in the fluid, may be disturbed in their function by the following influences:
- floating dirt
- growth of algae
- variations of the surface e.g. waves, position, etc.)
- oil coating of sight glasses
- contamination of flow cells
- etc.
Much maintenance is needed, to ensure the reliability of such instruments. Measurements based on sampling of the fluid have problems with oil and dirt covering. Due to thedifficulties with this measuring methods, it was sensefull to develope a non contact monitoring method. Since the oil usually floats we developed the idea of a sensor positioned above the water level. The detction should be done by using a suitable radiation method. Such a method is the surface detection of the electromagnetic rays caused by UV- stimulated flourescence. Thinn oil films on a water surface result in interference pattern easily recognized by the human eye. The flourescence method is by far more sensitive as the human eye and allows to detect oil layers of less than 3µm. The model FLUCOmat uses these method and provides highly sensitive and reproducable monitoring results paired with low maintenance.
The Fluorecence Method
-
UV-Radiation stimulates the oil to fluorescence
-
a highly sensitive detector recognizes the oil’s fluorescence
- the field transmitter converts the detector signals into measuring results
Even this method can be affected by:
- ambient light with extreme high intensity
- Large waves
- strong movement of the surface (waves, variations in water level, etc.)
- swimming debris at the surface
The technical conception of model FLUCmat and a well chosen measuring location minimize these effects.
Principle:
Radiant energy (E1 = h1) in the ultraviolet, can be absorbed by an atom or molecule, thus exciting electrons to a higher level of energy. Falling back to the ground state, the electrons emit a radiation (E2 = h2), with a higher wavelength as before absorption. The rest of the energy is emitted by the system in other forms, e.g. as kinetic energy (thermal radiation) (E3):
E1 = E2 + E3
The emitted wavelength (fluorescence radiation) is specific for the monitored oil. Sensitivity and selectivity can be influenced through selection of excitation and detection wavelength. The fluorescence detection method described here, has a sensitivity of one droplet (approx. 0,1ml) per m2 surface. However, this depends on the process conditions and on the installation of the system (flow rate, waves, distance from the surface, speed of flow, etc.).
Technical Realization Model FLUCOmat
The instrument is designed for continuous operation in industrial environments, a low maintenance requirement is guaranteed. The influences due to external disturbances are minimized.
UV- Lamps
To stimulate the fluorescence, UV- lamps or optional UV- LED arrays are taken as UV- Sources. These UV- Sources are arranged above the detector optic and cover a detection area of about 30cm diameter. This design allow detecting even from moving water surfaces, the sensitivity is not reduced by waves up to 3cm.
Detection optic
The receiver optic is adjusted for a distance of about 400mm instrument sensor and water surface. Variations of the distance (e.g. changes in water level) more than 75mm should be compensated by a suitable installation (e.g. installation at pontoons, using of an ultra sonic controlled lift system, bypass container, etc.).
Detection Components
A stability controlled Photomultiplier is used to recognize the fluorescence radiation. The modulation of the UV- Sources compensates for ambient light by demodulation of the receiving signals (see fig. 1).
Figure 1: Operating Principle of the Oil Monitoring System Model FLUCOmat
Status Signals
The correct functioning of the system is guaranteed by permanent self monitoring of the following parameter:
- UV intensity of each UV- source
- Modulation / Demodulation
- Sensitivity of Photomultiplier
- Power Supply
Malfunction warnings are displayed by four LED’s. A common relay is configured to transmit a failure or a malfunction warning to the control room. An isolated analog output (4-20mA) transfers the monitoring results to a control room.
Laboratory measurement:
Detection sensitivity of several oils, as detected by using a laboratory setup of the instrument.
Operational Experience
The device is already installed to many applications like:
- Oil at drinking water reservoirs
- Turbine Oil in power stations
- Hydraulic oil
- Oil in cooling water
- Oil of heat exchangers
- Oil in produced water
- Oil in water detention basins
- Water return plants to rivers/lakes
- Water return public water systems